{"id":1975,"date":"2021-06-11T15:03:34","date_gmt":"2021-06-11T07:03:34","guid":{"rendered":"https:\/\/www.hjkir.com\/?p=1975"},"modified":"2024-01-12T14:49:11","modified_gmt":"2024-01-12T06:49:11","slug":"%e9%ab%98%e7%82%89%e7%82%89%e9%a1%b6%e7%ba%a2%e5%a4%96%e7%83%ad%e5%83%8f%e7%b3%bb%e7%bb%9f","status":"publish","type":"post","link":"https:\/\/www.hjkir.com\/industry\/en\/1975.html","title":{"rendered":"Infrared thermal image system of blast furnace top"},"content":{"rendered":"<p>The blast furnace top imaging system is the main equipment to monitor and detect the material surface environment on the upper part of the blast furnace. The monitoring range includes the shape of the material surface inside the blast furnace, the air flow, the chute, the chute distribution, the real-time working condition of the equipment in the furnace such as the probe, nozzle, water spray, cooling stave, etc.<\/p>\n<p>Through timely understanding and mastering the charge level of the blast furnace throat and the distribution of gas flow, adjusting the blast furnace operation, maintaining the smooth and stable furnace condition, and improving various technical indicators, it plays an important role.<\/p>\n<h2><strong><b>Technical introduction<\/b><\/strong><\/h2>\n<p>The system is mainly composed of infrared thermal imager of blast furnace charge surface and protection and image processing device. The hardware structure diagram of the system is as follows:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-1976 size-full\" src=\"https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u56fe\u72471_\u526f\u672c-1.jpg\" alt=\"\u9ad8\u7089\u7089\u9876\u6210\u50cf\u7cfb\u7edf,\u9ad8\u7089\u7ea2\u5916,\u9ad8\u7089\u70ed\u50cf\u4eea\" width=\"600\" height=\"418\" srcset=\"https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u56fe\u72471_\u526f\u672c-1.jpg 600w, https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u56fe\u72471_\u526f\u672c-1-300x209.jpg 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<h2><strong><b>System function<\/b><\/strong><\/h2>\n<p>1. Real time monitoring the temperature distribution of the charge surface in the furnace before and after the distribution, as well as the distribution of materials;<\/p>\n<p>2. Real time monitoring of the material level in the furnace before and after the distribution and the operation of the equipment in the furnace (such as distribution chute and feeler);<\/p>\n<p>3. Multi point fixed-point temperature measurement and real-time temperature curve display;<\/p>\n<p>4. It can directly measure the temperature of any point in the temperature image;<\/p>\n<p>5. The temperature image at any time is stored in the way of hard disk storage, so as to query the historical data.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2005 size-large\" src=\"https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876-\u5c01\u9762\u56fe_\u526f\u672c-1024x436.jpg\" alt=\"\u9ad8\u7089\u7089\u9876\u7ea2\u5916\u56fe,\u9ad8\u7089\u7ea2\u5916\u70ed\u50cf\u4eea,\u7089\u7a91\u7ea2\u5916\" width=\"1024\" height=\"436\" srcset=\"https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876-\u5c01\u9762\u56fe_\u526f\u672c-1024x436.jpg 1024w, https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876-\u5c01\u9762\u56fe_\u526f\u672c-300x128.jpg 300w, https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876-\u5c01\u9762\u56fe_\u526f\u672c-768x327.jpg 768w, https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876-\u5c01\u9762\u56fe_\u526f\u672c-1536x654.jpg 1536w, https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876-\u5c01\u9762\u56fe_\u526f\u672c-2048x872.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2><strong><b>Main technical indicators:<\/b><\/strong><\/h2>\n<p>Field angle: above 90 \u00b0<\/p>\n<p>Spatial resolution: 5.1mard<\/p>\n<p>Detector type: uncooled focal plane<\/p>\n<p>Wavelength range: 8 ~ 14 \u00b5 M<\/p>\n<p>Temperature measurement range: 15 \u2103 ~ 2000 \u2103<\/p>\n<p>Accuracy: \u00b1 2 \u2103 or \u00b1 2%<\/p>\n<p>Working environment temperature: 0 \u2103 ~ 60 \u2103<\/p>\n<p>Video interface: network interface<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2006 size-full\" src=\"https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876\u884c\u4e1a\u5e94\u7528_\u526f\u672c\u6c34\u5370.jpg\" alt=\"\u7089\u7a91\u51b6\u91d1\u7ea2\u5916,\u7089\u7a91\u7ea2\u5916\u70ed\u50cf\u4eea,\u7089\u9876\u70ed\u6210\u50cf\" width=\"865\" height=\"455\" srcset=\"https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876\u884c\u4e1a\u5e94\u7528_\u526f\u672c\u6c34\u5370.jpg 865w, https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876\u884c\u4e1a\u5e94\u7528_\u526f\u672c\u6c34\u5370-300x158.jpg 300w, https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/06\/\u9ad8\u7089\u7089\u9876\u884c\u4e1a\u5e94\u7528_\u526f\u672c\u6c34\u5370-768x404.jpg 768w\" sizes=\"(max-width: 865px) 100vw, 865px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>Applicable Machine<\/h2>\n<div id=\"post_in_list2\" class=\"post_in_list_out\"> <ul class=\"post_in_list\"><li><div class=\"case_pic\">  <a href=\"https:\/\/www.hjkir.com\/industry\/en\/1228.html\"target=\"_blank\"><figure> <img decoding=\"async\" class=\"lazyload\" alt=\"K26E5 \u5728\u7ebf\u5f0f\u7ea2\u5916\u70ed\u6210\u50cf\u6d4b\u6e29\u4eea\" title=\"K26E5 Online Infrared Thermal Imaging Thermometer\" src=\"https:\/\/www.hjkir.com\/industry\/wp-content\/themes\/thousandfaceIHorizon\/images\/loading.png\"data-src=\"https:\/\/www.hjkir.com\/industry\/wp-content\/uploads\/2021\/03\/K26E5-1-1-300x300.jpg\" \/><\/figure><\/a><\/div><div class=\"case_text\"> \n <h4  class=\"posts_titles\">   <a href=\"https:\/\/www.hjkir.com\/industry\/en\/1228.html\"target=\"_blank\">K26E5 Online Infrared Thermal Imaging Thermometer<\/a><\/h4>\n \n <\/div><\/ul><\/div>","protected":false},"excerpt":{"rendered":"<p>The blast furnace top imaging system is the main equipment to monitor and detect the upper charge surface environment of the blast furnace. The monitoring range includes the shape of the charge surface inside the blast furnace, the air flow, the chute, and the chute distribution [...]<\/p>","protected":false},"author":1,"featured_media":1978,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[48,7],"tags":[146,145,144,143],"_links":{"self":[{"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/posts\/1975"}],"collection":[{"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/comments?post=1975"}],"version-history":[{"count":8,"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/posts\/1975\/revisions"}],"predecessor-version":[{"id":7767,"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/posts\/1975\/revisions\/7767"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/media\/1978"}],"wp:attachment":[{"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/media?parent=1975"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/categories?post=1975"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hjkir.com\/industry\/en\/wp-json\/wp\/v2\/tags?post=1975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}