S300B Technical Parameter

Detector TypeUncooled Focal Plane Microbolometer
Resolution384×288
Pixel Size17um
Spectral Range8~14um
热灵敏度(NETD)≤50mk@ 30℃
Frame Rate25Hz
Infrared lens8mm F#0.8
红外镜头视场角44.0°×34.0°
可见光
可见光分辨率1920×1080
黑体
工作温度范围5℃~60℃
辐射面80mm×80mm
温度分辨率0.1℃
Temperature Measurement Accuracy±0.2℃(35℃)
温度稳定性±(0.1~0.2)℃/30min
测温性能
Measuring Range30℃~42℃
Temperature Measurement Accuracy±0.3℃
温度校准自校准
Interface
Data InterfaceRJ45
Web StandardGigE
Protocol Support默认UDP
Input Power Supply Voltage12VDC
Environmental Parameters
Operation Temperature在-20~60℃范围内可工作,在15~40℃范围内可保证测温精度
Storage Temperature-40℃~70℃
Humidity≤85%(非冷凝)
Physical Characteristics
Size205mm×124mm×275mm
黑体尺寸150mm×144mm×288mm

 

Abnormal operation of upper computer

Possible causes:
  1. The necessary runtime library (EXE or credist_vs2013.x86.exe under the installation software directory) is missing
  2. The software does not support the operating system used (replace the operating system or computer)

The software cannot detect the camera IP address

Possible causes:
  1. The computer firewall blocks network transmission (turn off the firewall, or add the software to the firewall white list)

The software detects the IP address of the camera, but there is no image output or image jam

Possible causes:
  1. Insufficient bandwidth (check whether the camera network card is gigabit network. It is recommended to use gigabit network. The 100m network camera will automatically reduce the frame rate)
  2. Network card configuration problem (for 100Hz or 200Hz high frame rate cameras, you need to turn on the giant frame function of the network card)
  3. The computer local IP is not in the same network segment as the camera IP (modify the computer local link IP address, which is in the same network segment as the camera, and is not the same as the camera
  4. The software does not support the operating system used (replace the operating system or computer)

Large temperature measurement deviation

Possible causes:
  1. The use environment is beyond the scope of product use (use appropriate cooling measures)
  2. The use environment is beyond the scope of product use (use appropriate cooling measures)

The image flickers or there is a splash screen phenomenon

Possible causes:
  1. The power supply voltage or power does not meet the requirements of the camera (replace the power supply)
  2. Camera hardware failure (return to factory for maintenance)