KD23/KD26系列电动调焦红外热像仪

KD23/KD26系列电动调焦红外热像仪

Product Profile

KD series online infrared thermal imaging thermometer adopts 17 μ M uncooled infrared focal plane detector, high-performance infrared lens and signal processing circuit, and embedded with advanced image processing algorithm, it has the characteristics of small size, low power consumption, fast startup, excellent imaging quality, accurate temperature measurement and so on.

The device selection of KD series on-line infrared thermal imaging thermometer fully considers the requirements of high and low temperature working performance to ensure that the whole machine has excellent environmental adaptability.

Functional Characteristics

  1. It has all-weather passive thermal imaging function, has strong smoke penetration performance, and can be used in a wide range of ambient temperatures;
  2. With high frame rate design, fast-moving targets can be observed;
  3. Adopt self-developed temperature measurement correction algorithm to realize accurate temperature measurement;
  4. The full stream lossless 16bit temperature data is output, and the client software and SDK development kit are provided to facilitate the secondary development and system integration of customers, and fully carry out personalized temperature analysis of the tested target.

Application Field

Iron And Steel Metallurgy, Petroleum And Petrochemical, Rail Transit, Scientific Research

Power Grid, Machine Vision, Customized Development

IR Detector
Detector TypeUncooled Focal Plane Microbolometer
Resolution384×288/640×480
Pixel Size17μm
Spectral Range8~14μm
NETD≤50mk@30℃
Frame Rate≤ 50Hz (configurable)
Image Processing And Display
Start-up Time≤15S
PaletteA variety of color palettes, including white heat, black heat, iron red, rainbow, etc
Contrast And Brightness自动 / 手动
Data Format16bit Temperature Data (full Code Stream)
Temperature Measurement Analysis
Temperature Measurement Accuracy±2℃ or ±2%
Measuring RangeNormal Temperature Range: -20 ℃ ~ 200 ℃
Medium Temperature Range: 50 ℃ ~ 800 ℃
High Temperature Range: 50 ℃ ~ 1600 ℃
Electrical Characteristics
Data InterfaceRJ45
Web Standard100M Network / Gigabit Network (100M network needs to reduce the frame rate)
Protocol SupportUDP
Power Interface2EDGKD-3.81mm/2P
Input Power Supply Voltage5V~12VDC
Communication InterfaceUART@RS485 (anti control platform and camera)
Steady State Power Consumption<2.5W
Reverse Connection ProtectionHave
Overvoltage And Undervoltage ProtectionHave
Environmental Parameters
Operation Temperature-40 ℃ ~ 60 ℃ (-20 ℃ ~ 60 ℃ to ensure temperature measurement accuracy
Storage Temperature-45℃~70℃
Resistance To Temperature Shock5℃/min(-40℃~60℃)
Vibration Resistance4.3g, 2 hours for each axis of x, y and z axes
Shock ResistanceAcceleration 30g, Half Sine Wave, Pulse Width 6ms, Impact 3 Times In The Direction Of Installation And Use
Humidity≤ 95% (non condensing)
Camera Lens
Focal Length4.8、5.7、8、9.6、13、19、25、35、50mm(可选配)
Focus ModeElectric
Clear Imaging Range0.3m~∞
Physical Characteristics
Overall Dimension79.3mm×45mm×58mm(不含镜头)
Weight<205g
Mounting Hole14-M3×4
Client
Real Time Temperature DisplaySupport
Multiple Temperature Measuring ObjectsSupport
Caution FunctionSupport
Video Recording / Photographing / PlaybackSupport
SDK development kit
Operating Environment支持win32、x64、Linux(x86/ARM)
数据获取通过回调函数获取16Bit温度数据(全码流)

Abnormal operation of upper computer

Possible causes:
  1. The necessary runtime library (EXE or credist_vs2013.x86.exe under the installation software directory) is missing
  2. The software does not support the operating system used (replace the operating system or computer)

The software cannot detect the camera IP address

Possible causes:
  1. The computer firewall blocks network transmission (turn off the firewall, or add the software to the firewall white list)

The software detects the IP address of the camera, but there is no image output or image jam

Possible causes:
  1. Insufficient bandwidth (check whether the camera network card is gigabit network. It is recommended to use gigabit network. The 100m network camera will automatically reduce the frame rate)
  2. Network card configuration problem (for 100Hz or 200Hz high frame rate cameras, you need to turn on the giant frame function of the network card)
  3. The computer local IP is not in the same network segment as the camera IP (modify the computer local link IP address, which is in the same network segment as the camera, and is not the same as the camera
  4. The software does not support the operating system used (replace the operating system or computer)

Large temperature measurement deviation

Possible causes:
  1. The use environment is beyond the scope of product use (use appropriate cooling measures)
  2. The use environment is beyond the scope of product use (use appropriate cooling measures)

The image flickers or there is a splash screen phenomenon

Possible causes:
  1. The power supply voltage or power does not meet the requirements of the camera (replace the power supply)
  2. Camera hardware failure (return to factory for maintenance)
Label:Rotary kiln infraredElectric Infrared Thermal ImagerMolten iron thermometer Previous: Next:
展开更多
免费预约体验课程

loading...

This site is protected by wp-copyrightpro.com

error: 未经授权,请勿拷贝!
WeChat Tel:400-080-4288