HIRDA-NK-A内窥式气动 超高温红外热成像温度检测与分析系统

HIRDA-NK-A内窥式气动 超高温红外热成像温度检测与分析系统

Product Profile

HIRDA-NK-A系列内窥式气动超高温红外热成像温度检测与分析系统是一款专门运用于高温环境的特种闭路电视设备,系统由红外热成像机芯、耐高温红外热成像镜头、自动回缩保护装置、炉壁安装套件、空气过滤系统和现场设备箱、算法服务器以及智能测温软件等组成。

将耐高温红外热成像镜头安装在能够伸缩的金属防护罩中,通过伸缩装置将耐高温红外热成像镜头直接伸入至窑炉内(1600℃以下),红外热成像机芯停留在炉外,实现对炉内运行工作状态的连续实时监视。

通过压缩的冷却空气或冷却水,对护罩进行冷却,使红外镜头工作在较适宜的温度;同时对镜头进行吹扫,防止炉内灰尘附着在镜头保护窗口上;系统内置高温保护电路,一旦冷却气体或冷却水发生循环异常,即回缩镜头,防止被炉内高温损伤。

具有耐高温、耐腐蚀、免维护的特点,能够实时显示窑炉内部各种复杂的工况,在摄像探头吹扫压缩空气正常的情况下,适用于各种正压窑炉。

Functional Characteristics

  • 具备全天候被动红外测温功能
  • 采用自研测温校正算法,实现精确温度测量
  • 支持onvif协议,可接入主流NVR;
  • 不依赖系统平台,可直接网页登录ip进行访问图像和配置,可直接输出报警信号到PLC或者报警器;
  • 伸缩长度可定制,适合各种壁厚的窑炉
  • 螺旋风幕设计,镜头不积灰
  • 整体不锈钢材料,耐腐耐温
  • 直视型内窥镜头
  • 自动退出保护装置, 退出故障指示
  • 气动传动机构
  • 耐高温光学针孔镜头,带防尘高温镜片
  • 超温、欠压、停电自动退出炉膛

Scope Of Application

水泥厂窑头、篦冷机落料、钢铁厂加热炉、退火炉、热处理炉,垃圾处理厂焚烧炉等工业高温炉。

一、上位机运行异常
Possible causes:
The necessary runtime library (EXE or credist_vs2013.x86.exe under the installation software directory) is missing
The software does not support the operating system used (replace the operating system or computer)
二、软件检测不到相机IP地址
Possible causes:
The computer firewall blocks network transmission (turn off the firewall, or add the software to the firewall white list)
The software detects the IP address of the camera, but there is no image output or image jam
Possible causes:
Insufficient bandwidth (check whether the camera network card is gigabit network. It is recommended to use gigabit network. The 100m network camera will automatically reduce the frame rate)
Network card configuration problem (for 100Hz or 200Hz high frame rate cameras, you need to turn on the giant frame function of the network card)
The computer local IP is not in the same network segment as the camera IP (modify the computer local link IP address, which is in the same network segment as the camera, and is not the same as the camera
The software does not support the operating system used (replace the operating system or computer)
四、测温偏差大
Possible causes:
The use environment is beyond the scope of product use (use appropriate cooling measures)
Temperature section mismatch (select the appropriate temperature section for temperature measurement)
五、图像闪烁或出现花屏现象
Possible causes:
The power supply voltage or power does not meet the requirements of the camera (replace the power supply)
Camera hardware failure (return to factory for maintenance)